Bus Plug Neutral Kits

A bus plug neutral kit adds a neutral stab and terminal to a bus plug, so that a 3-wire plug can serve a 4-wire circuit. BRAH Electric lists 43 neutral kits for Siemens and ITE, Cutler-Hammer, Square D and General Electric bus plugs and for BRAH substitute plugs. Most are rated for 30A to 100A plugs at 600V, with 200A kits for most families and a few larger ones up to 600A. Each listing shows amperage, voltage and the bus plug family and type the kit suits.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

53 Results(Showing 1 - 20)
B3F100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitablePOW-R-WAY III
Type(s) SuitableBIP
BRAH BDH100N Neutral Kit
BDH100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableType DH
Type(s) SuitableBDH
BRAH BEK100N Neutral Kit
BEK100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableType FVK
Type(s) SuitableBEK
BRAH BES100N Neutral Kit
BES100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableBD Series
Type(s) SuitableBES
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BIP100N Neutral Kit
BIP100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitablePOW-R-WAY I and II
Type(s) SuitableBIP
BRAH BN100 Neutral Kit
BN100
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableArmor Clad, Spectra, Spectra Low-Amp
Type(s) SuitableBEB, BEL, BEC
BRAH BOSN100A240V Neutral Kit
BOSN100A240V
View Product
Amperage100A
Voltage240V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BRAH BOSN100A600V Neutral Kit
BOSN100A600V
View Product
Amperage100A
Voltage600V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BRAH BOSN200A240V Neutral Kit
BOSN200A240V
View Product
Amperage200A
Voltage240V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BRAH BOSN200A600V Neutral Kit
BOSN200A600V
View Product
Amperage200A
Voltage600V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BRAH BOSN60A240V Neutral Kit
BOSN60A240V
View Product
Amperage30A - 60A
Voltage240V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BRAH BOSN60A600V Neutral Kit
BOSN60A600V
View Product
Amperage30A - 60A
Voltage600V
Family(s) SuitableBD Series
Type(s) SuitableBOS
BPQ100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableI-Line I and I-Line II
Type(s) SuitableBIP
BRV100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableXL-X Series
Type(s) SuitableBRV
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BUV100N Neutral Kit
BUV100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableXL-U
Type(s) SuitableBUV
BRAH FVK100N Neutral Kit
FVK100N
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitableType FVK
Type(s) SuitableFVK
BRAH FVK200N Neutral Kit
FVK200N
View Product
Amperage200A
Voltage600V
Family(s) SuitableType FVK
Type(s) SuitableFVK
BRAH ITAP100N Neutral Kit – replaces Cutler Hammer PWN110
ITAP100N
Substitute for Cutler Hammer PWN110, 2528D04G03
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitablePOW-R-WAY I and II
Type(s) SuitableITAP
Cutler Hammer PWN110 replacement Neutral Kit – BRAH ITAP100N
PWN110
BRAH ITAP100N is the direct substitute for Cutler Hammer PWN110
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitablePOW-R-WAY I and II
Type(s) SuitableITAP
Cutler Hammer 2528D04G03 replacement Neutral Kit – BRAH ITAP100N
2528D04G03
BRAH ITAP100N is the direct substitute for Cutler Hammer 2528D04G03
View Product
Amperage30A - 100A
Voltage600V
Family(s) SuitablePOW-R-WAY I and II
Type(s) SuitableITAP

Neutral kits by busway family and plug type

Overview

Coverage by busway family: Square D I-Line I & II (type PQ, and breaker type plugs); Siemens and ITE BD Series (type BOS), XL-U Series (type UV), XL-X Series (type RV) and Sentron (type SLID); Cutler-Hammer POW-R-WAY I & II (type ITAP), POW-R-WAY III (type P3F) and Standard Design (type TAP); and General Electric Armor Clad, Spectra and Spectra Low-Amp (types AC, SB and SL), Type FVK and Type DH. Kits made for BRAH substitute plugs, such as BEK100N for type BEK and BES100N for type BES, are described as such.

Several Cutler-Hammer kits replace a specific OEM part number: PWN110, PWNF250, PWN400 and PWN600 for ITAP plugs, P3FN100 and P3FN200 for P3F plugs, and N110 for TAP plugs. A few kits have limits worth checking. PQ100N fits only the newer vertical-mount PQ plugs, NG100 is a combined neutral and ground assembly, and the BD Series kits are also listed in 240V versions.

How do I choose a bus plug neutral kit?

To choose, match the busway family and plug type first, then the plug amperage, and check whether the kit is for the OEM plug or the BRAH substitute. Neutral kits carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.