Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 1 - 20)
BRAH BARP040 Rating Plug – replaces Square D ARP040
BARP040
Substitute for Square D ARP040
View Product
FamilyARP Series
Amperage40%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP040 replacement Rating Plug – BRAH BARP040
ARP040
BRAH BARP040 is the direct substitute for Square D ARP040
View Product
FamilyARP Series
Amperage40%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP050 Rating Plug – replaces Square D ARP050
BARP050
Substitute for Square D ARP050
View Product
FamilyARP Series
Amperage50%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP050 replacement Rating Plug – BRAH BARP050
ARP050
BRAH BARP050 is the direct substitute for Square D ARP050
View Product
FamilyARP Series
Amperage50%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BARP056 Rating Plug – replaces Square D ARP056
BARP056
Substitute for Square D ARP056
View Product
FamilyARP Series
Amperage56%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP056 replacement Rating Plug – BRAH BARP056
ARP056
BRAH BARP056 is the direct substitute for Square D ARP056
View Product
FamilyARP Series
Amperage56%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP058 Rating Plug – replaces Square D ARP058
BARP058
Substitute for Square D ARP058
View Product
FamilyARP Series
Amperage58%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP058 replacement Rating Plug – BRAH BARP058
ARP058
BRAH BARP058 is the direct substitute for Square D ARP058
View Product
FamilyARP Series
Amperage58%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP060 Rating Plug – replaces Square D ARP060
BARP060
Substitute for Square D ARP060
View Product
FamilyARP Series
Amperage60%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP060 replacement Rating Plug – BRAH BARP060
ARP060
BRAH BARP060 is the direct substitute for Square D ARP060
View Product
FamilyARP Series
Amperage60%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP063 Rating Plug – replaces Square D ARP063
BARP063
Substitute for Square D ARP063
View Product
FamilyARP Series
Amperage63%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP063 replacement Rating Plug – BRAH BARP063
ARP063
BRAH BARP063 is the direct substitute for Square D ARP063
View Product
FamilyARP Series
Amperage63%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP067 Rating Plug – replaces Square D ARP067
BARP067
Substitute for Square D ARP067
View Product
FamilyARP Series
Amperage67%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP067 replacement Rating Plug – BRAH BARP067
ARP067
BRAH BARP067 is the direct substitute for Square D ARP067
View Product
FamilyARP Series
Amperage67%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BARP070 Rating Plug – replaces Square D ARP070
BARP070
Substitute for Square D ARP070
View Product
FamilyARP Series
Amperage70%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP070 replacement Rating Plug – BRAH BARP070
ARP070
BRAH BARP070 is the direct substitute for Square D ARP070
View Product
FamilyARP Series
Amperage70%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP075 Rating Plug – replaces Square D ARP075
BARP075
Substitute for Square D ARP075
View Product
FamilyARP Series
Amperage75%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP075 replacement Rating Plug – BRAH BARP075
ARP075
BRAH BARP075 is the direct substitute for Square D ARP075
View Product
FamilyARP Series
Amperage75%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP080 Rating Plug – replaces Square D ARP080
BARP080
Substitute for Square D ARP080
View Product
FamilyARP Series
Amperage80%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP080 replacement Rating Plug – BRAH BARP080
ARP080
BRAH BARP080 is the direct substitute for Square D ARP080
View Product
FamilyARP Series
Amperage80%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.