Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 21 - 40)
BRAH BARP083 Rating Plug – replaces Square D ARP083
BARP083
Substitute for Square D ARP083
View Product
FamilyARP Series
Amperage83%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP083 replacement Rating Plug – BRAH BARP083
ARP083
BRAH BARP083 is the direct substitute for Square D ARP083
View Product
FamilyARP Series
Amperage83%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP088 Rating Plug – replaces Square D ARP088
BARP088
Substitute for Square D ARP088
View Product
FamilyARP Series
Amperage88%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP088 replacement Rating Plug – BRAH BARP088
ARP088
BRAH BARP088 is the direct substitute for Square D ARP088
View Product
FamilyARP Series
Amperage88%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BARP090 Rating Plug – replaces Square D ARP090
BARP090
Substitute for Square D ARP090
View Product
FamilyARP Series
Amperage90%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP090 replacement Rating Plug – BRAH BARP090
ARP090
BRAH BARP090 is the direct substitute for Square D ARP090
View Product
FamilyARP Series
Amperage90%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BARP100 Rating Plug – replaces Square D ARP100
BARP100
Substitute for Square D ARP100
View Product
FamilyARP Series
Amperage100%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
Square D ARP100 replacement Rating Plug – BRAH BARP100
ARP100
BRAH BARP100 is the direct substitute for Square D ARP100
View Product
FamilyARP Series
Amperage100%
Frame Type SuitableAll Square D Breakers with MicroLogic Series 3B Trip Units
Max Frame Amp 
BRAH BE-04SB200 Rating Plug – replaces Siemens 04SB200
BE-04SB200
Substitute for Siemens 04SB200
View Product
FamilySB Series
Amperage200A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB200 replacement Rating Plug – BRAH BE-04SB200
04SB200
BRAH BE-04SB200 is the direct substitute for Siemens 04SB200
View Product
FamilySB Series
Amperage200A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
BRAH BE-04SB225 Rating Plug – replaces Siemens 04SB225
BE-04SB225
Substitute for Siemens 04SB225
View Product
FamilySB Series
Amperage225A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB225 replacement Rating Plug – BRAH BE-04SB225
04SB225
BRAH BE-04SB225 is the direct substitute for Siemens 04SB225
View Product
FamilySB Series
Amperage225A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
BRAH BE-04SB250 Rating Plug – replaces Siemens 04SB250
BE-04SB250
Substitute for Siemens 04SB250
View Product
FamilySB Series
Amperage250A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB250 replacement Rating Plug – BRAH BE-04SB250
04SB250
BRAH BE-04SB250 is the direct substitute for Siemens 04SB250
View Product
FamilySB Series
Amperage250A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BE-04SB300 Rating Plug – replaces Siemens 04SB300
BE-04SB300
Substitute for Siemens 04SB300
View Product
FamilySB Series
Amperage300A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB300 replacement Rating Plug – BRAH BE-04SB300
04SB300
BRAH BE-04SB300 is the direct substitute for Siemens 04SB300
View Product
FamilySB Series
Amperage300A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
BRAH BE-04SB350 Rating Plug – replaces Siemens 04SB350
BE-04SB350
Substitute for Siemens 04SB350
View Product
FamilySB Series
Amperage350A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB350 replacement Rating Plug – BRAH BE-04SB350
04SB350
BRAH BE-04SB350 is the direct substitute for Siemens 04SB350
View Product
FamilySB Series
Amperage350A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
BRAH BE-04SB400 Rating Plug – replaces Siemens 04SB400
BE-04SB400
Substitute for Siemens 04SB400
View Product
FamilySB Series
Amperage400A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A
Siemens 04SB400 replacement Rating Plug – BRAH BE-04SB400
04SB400
BRAH BE-04SB400 is the direct substitute for Siemens 04SB400
View Product
FamilySB Series
Amperage400A
Frame Type SuitableSBA, SBH, SBS
Max Frame Amp400A

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.