Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 201 - 220)
BRAH BE-SRPG600A250 Rating Plug – replaces General Electric SRPG600A250
BE-SRPG600A250
Substitute for General Electric SRPG600A250
View Product
FamilySpectra Series
Amperage250
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A250 replacement Rating Plug – BRAH BE-SRPG600A250
SRPG600A250
BRAH BE-SRPG600A250 is the direct substitute for General Electric SRPG600A250
View Product
FamilySpectra Series
Amperage250
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH BE-SRPG600A300 Rating Plug – replaces General Electric SRPG600A300
BE-SRPG600A300
Substitute for General Electric SRPG600A300
View Product
FamilySpectra Series
Amperage300
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A300 replacement Rating Plug – BRAH BE-SRPG600A300
SRPG600A300
BRAH BE-SRPG600A300 is the direct substitute for General Electric SRPG600A300
View Product
FamilySpectra Series
Amperage300
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BE-SRPG600A350 Rating Plug – replaces General Electric SRPG600A350
BE-SRPG600A350
Substitute for General Electric SRPG600A350
View Product
FamilySpectra Series
Amperage350
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A350 replacement Rating Plug – BRAH BE-SRPG600A350
SRPG600A350
BRAH BE-SRPG600A350 is the direct substitute for General Electric SRPG600A350
View Product
FamilySpectra Series
Amperage350
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH BE-SRPG600A400 Rating Plug – replaces General Electric SRPG600A400
BE-SRPG600A400
Substitute for General Electric SRPG600A400
View Product
FamilySpectra Series
Amperage400
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A400 replacement Rating Plug – BRAH BE-SRPG600A400
SRPG600A400
BRAH BE-SRPG600A400 is the direct substitute for General Electric SRPG600A400
View Product
FamilySpectra Series
Amperage400
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH BE-SRPG600A450 Rating Plug – replaces General Electric SRPG600A450
BE-SRPG600A450
Substitute for General Electric SRPG600A450
View Product
FamilySpectra Series
Amperage450
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A450 replacement Rating Plug – BRAH BE-SRPG600A450
SRPG600A450
BRAH BE-SRPG600A450 is the direct substitute for General Electric SRPG600A450
View Product
FamilySpectra Series
Amperage450
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH BE-SRPG600A500 Rating Plug – replaces General Electric SRPG600A500
BE-SRPG600A500
Substitute for General Electric SRPG600A500
View Product
FamilySpectra Series
Amperage500
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A500 replacement Rating Plug – BRAH BE-SRPG600A500
SRPG600A500
BRAH BE-SRPG600A500 is the direct substitute for General Electric SRPG600A500
View Product
FamilySpectra Series
Amperage500
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH BE-SRPG600A600 Rating Plug – replaces General Electric SRPG600A600
BE-SRPG600A600
Substitute for General Electric SRPG600A600
View Product
FamilySpectra Series
Amperage600
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
General Electric SRPG600A600 replacement Rating Plug – BRAH BE-SRPG600A600
SRPG600A600
BRAH BE-SRPG600A600 is the direct substitute for General Electric SRPG600A600
View Product
FamilySpectra Series
Amperage600
Frame Type SuitableSGDA,SGHA,SGLA,SGPA
Max Frame Amp600
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BE-SRPK1200A1000
Substitute for General Electric SRPK1200A1000
View Product
FamilySpectra Series
Amperage1000
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200
SRPK1200A1000
BRAH BE-SRPK1200A1000 is the direct substitute for General Electric SRPK1200A1000
View Product
FamilySpectra Series
Amperage1000
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200
BRAH BE-SRPK1200A1200 Rating Plug – replaces General Electric SRPK1200A1200
BE-SRPK1200A1200
Substitute for General Electric SRPK1200A1200
View Product
FamilySpectra Series
Amperage1200
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200
General Electric SRPK1200A1200 replacement Rating Plug – BRAH BE-SRPK1200A1200
SRPK1200A1200
BRAH BE-SRPK1200A1200 is the direct substitute for General Electric SRPK1200A1200
View Product
FamilySpectra Series
Amperage1200
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200
BE-SRPK1200A600
Substitute for General Electric SRPK1200A600
View Product
FamilySpectra Series
Amperage600
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200
SRPK1200A600
BRAH BE-SRPK1200A600 is the direct substitute for General Electric SRPK1200A600
View Product
FamilySpectra Series
Amperage600
Frame Type SuitableSKDA,SKHA,SKLA,SKPA
Max Frame Amp1200

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.