Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 341 - 360)
BRAH BE-TR32S2400 Rating Plug – replaces General Electric TR32S2400
BE-TR32S2400
Substitute for General Electric TR32S2400
View Product
FamilyAKR Series
Amperage2400A
Frame Type SuitableAKR75
Max Frame Amp3200A
General Electric TR32S2400 replacement Rating Plug – BRAH BE-TR32S2400
TR32S2400
BRAH BE-TR32S2400 is the direct substitute for General Electric TR32S2400
View Product
FamilyAKR Series
Amperage2400A
Frame Type SuitableAKR75
Max Frame Amp3200A
BRAH BE-TR32S3200 Rating Plug – replaces General Electric TR32S3200
BE-TR32S3200
Substitute for General Electric TR32S3200
View Product
FamilyAKR Series
Amperage3200A
Frame Type SuitableAKR75
Max Frame Amp3200A
General Electric TR32S3200 replacement Rating Plug – BRAH BE-TR32S3200
TR32S3200
BRAH BE-TR32S3200 is the direct substitute for General Electric TR32S3200
View Product
FamilyAKR Series
Amperage3200A
Frame Type SuitableAKR75
Max Frame Amp3200A
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BE-TR40B2000 Rating Plug – replaces General Electric TR40B2000
BE-TR40B2000
Substitute for General Electric TR40B2000
View Product
FamilyMicroVersaTrip +
Amperage2000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
General Electric TR40B2000 replacement Rating Plug – BRAH BE-TR40B2000
TR40B2000
BRAH BE-TR40B2000 is the direct substitute for General Electric TR40B2000
View Product
FamilyMicroVersaTrip +
Amperage2000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
BRAH BE-TR40B2500 Rating Plug – replaces General Electric TR40B2500
BE-TR40B2500
Substitute for General Electric TR40B2500
View Product
FamilyMicroVersaTrip +
Amperage2500A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
General Electric TR40B2500 replacement Rating Plug – BRAH BE-TR40B2500
TR40B2500
BRAH BE-TR40B2500 is the direct substitute for General Electric TR40B2500
View Product
FamilyMicroVersaTrip +
Amperage2500A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
BRAH BE-TR40B3000 Rating Plug – replaces General Electric TR40B3000
BE-TR40B3000
Substitute for General Electric TR40B3000
View Product
FamilyMicroVersaTrip +
Amperage3000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
General Electric TR40B3000 replacement Rating Plug – BRAH BE-TR40B3000
TR40B3000
BRAH BE-TR40B3000 is the direct substitute for General Electric TR40B3000
View Product
FamilyMicroVersaTrip +
Amperage3000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
BRAH BE-TR40B4000 Rating Plug – replaces General Electric TR40B4000
BE-TR40B4000
Substitute for General Electric TR40B4000
View Product
FamilyMicroVersaTrip +
Amperage4000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
General Electric TR40B4000 replacement Rating Plug – BRAH BE-TR40B4000
TR40B4000
BRAH BE-TR40B4000 is the direct substitute for General Electric TR40B4000
View Product
FamilyMicroVersaTrip +
Amperage4000A
Frame Type SuitablePower Break II, AKR
Max Frame Amp4000A
BRAH BE-TR40S1600 Rating Plug – replaces General Electric TR40S1600
BE-TR40S1600
Substitute for General Electric TR40S1600
View Product
FamilyPower Break I
Amperage1600A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
General Electric TR40S1600 replacement Rating Plug – BRAH BE-TR40S1600
TR40S1600
BRAH BE-TR40S1600 is the direct substitute for General Electric TR40S1600
View Product
FamilyPower Break I
Amperage1600A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BE-TR40S2000 Rating Plug – replaces General Electric TR40S2000
BE-TR40S2000
Substitute for General Electric TR40S2000
View Product
FamilyPower Break I
Amperage2000A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
General Electric TR40S2000 replacement Rating Plug – BRAH BE-TR40S2000
TR40S2000
BRAH BE-TR40S2000 is the direct substitute for General Electric TR40S2000
View Product
FamilyPower Break I
Amperage2000A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
BRAH BE-TR40S2500 Rating Plug – replaces General Electric TR40S2500
BE-TR40S2500
Substitute for General Electric TR40S2500
View Product
FamilyPower Break I
Amperage2500A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
General Electric TR40S2500 replacement Rating Plug – BRAH BE-TR40S2500
TR40S2500
BRAH BE-TR40S2500 is the direct substitute for General Electric TR40S2500
View Product
FamilyPower Break I
Amperage2500A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
BRAH BE-TR40S3000 Rating Plug – replaces General Electric TR40S3000
BE-TR40S3000
Substitute for General Electric TR40S3000
View Product
FamilyPower Break I
Amperage3000A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A
General Electric TR40S3000 replacement Rating Plug – BRAH BE-TR40S3000
TR40S3000
BRAH BE-TR40S3000 is the direct substitute for General Electric TR40S3000
View Product
FamilyPower Break I
Amperage3000A
Frame Type SuitableTP, TC, THP, THC, AKR100
Max Frame Amp4000A

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.