Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 141 - 160)
BRAH BE-SRPE30A20 Rating Plug – replaces General Electric SRPE30A20
BE-SRPE30A20
Substitute for General Electric SRPE30A20
View Product
FamilySpectra Series
Amperage20
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
General Electric SRPE30A20 replacement Rating Plug – BRAH BE-SRPE30A20
SRPE30A20
BRAH BE-SRPE30A20 is the direct substitute for General Electric SRPE30A20
View Product
FamilySpectra Series
Amperage20
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
BRAH BE-SRPE30A25 Rating Plug – replaces General Electric SRPE30A25
BE-SRPE30A25
Substitute for General Electric SRPE30A25
View Product
FamilySpectra Series
Amperage25
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
General Electric SRPE30A25 replacement Rating Plug – BRAH BE-SRPE30A25
SRPE30A25
BRAH BE-SRPE30A25 is the direct substitute for General Electric SRPE30A25
View Product
FamilySpectra Series
Amperage25
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BE-SRPE30A30 Rating Plug – replaces General Electric SRPE30A30
BE-SRPE30A30
Substitute for General Electric SRPE30A30
View Product
FamilySpectra Series
Amperage30
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
General Electric SRPE30A30 replacement Rating Plug – BRAH BE-SRPE30A30
SRPE30A30
BRAH BE-SRPE30A30 is the direct substitute for General Electric SRPE30A30
View Product
FamilySpectra Series
Amperage30
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
BE-SRPE60A35
Substitute for General Electric SRPE60A35
View Product
FamilySpectra Series
Amperage35
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
SRPE60A35
BRAH BE-SRPE60A35 is the direct substitute for General Electric SRPE60A35
View Product
FamilySpectra Series
Amperage35
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
BRAH BE-SRPE60A40 Rating Plug – replaces General Electric SRPE60A40
BE-SRPE60A40
Substitute for General Electric SRPE60A40
View Product
FamilySpectra Series
Amperage40
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
General Electric SRPE60A40 replacement Rating Plug – BRAH BE-SRPE60A40
SRPE60A40
BRAH BE-SRPE60A40 is the direct substitute for General Electric SRPE60A40
View Product
FamilySpectra Series
Amperage40
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
BE-SRPE60A45
Substitute for General Electric SRPE60A45
View Product
FamilySpectra Series
Amperage45
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
SRPE60A45
BRAH BE-SRPE60A45 is the direct substitute for General Electric SRPE60A45
View Product
FamilySpectra Series
Amperage45
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
BRAH BE-SRPE60A50 Rating Plug – replaces General Electric SRPE60A50
BE-SRPE60A50
Substitute for General Electric SRPE60A50
View Product
FamilySpectra Series
Amperage50
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
General Electric SRPE60A50 replacement Rating Plug – BRAH BE-SRPE60A50
SRPE60A50
BRAH BE-SRPE60A50 is the direct substitute for General Electric SRPE60A50
View Product
FamilySpectra Series
Amperage50
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BE-SRPE60A60 Rating Plug – replaces General Electric SRPE60A60
BE-SRPE60A60
Substitute for General Electric SRPE60A60
View Product
FamilySpectra Series
Amperage60
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
General Electric SRPE60A60 replacement Rating Plug – BRAH BE-SRPE60A60
SRPE60A60
BRAH BE-SRPE60A60 is the direct substitute for General Electric SRPE60A60
View Product
FamilySpectra Series
Amperage60
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp60
BE-SRPE7A7
Substitute for General Electric SRPE7A7
View Product
FamilySpectra Series
Amperage7
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
SRPE7A7
BRAH BE-SRPE7A7 is the direct substitute for General Electric SRPE7A7
View Product
FamilySpectra Series
Amperage7
Frame Type SuitableSEDA,SEHA,SELA,SEPA
Max Frame Amp30
BRAH BE-SRPF250A100 Rating Plug – replaces General Electric SRPF250A100
BE-SRPF250A100
Substitute for General Electric SRPF250A100
View Product
FamilySpectra Series
Amperage100
Frame Type SuitableSFDA,SFHA,SFLA,SFPA
Max Frame Amp250
General Electric SRPF250A100 replacement Rating Plug – BRAH BE-SRPF250A100
SRPF250A100
BRAH BE-SRPF250A100 is the direct substitute for General Electric SRPF250A100
View Product
FamilySpectra Series
Amperage100
Frame Type SuitableSFDA,SFHA,SFLA,SFPA
Max Frame Amp250

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.