Magnetic Coils for Contactors

A magnetic coil is the electromagnet inside a contactor: when control voltage is applied the coil pulls the contacts closed, and when it is removed the contactor drops out. On these contactors a failed coil can be replaced without replacing the contactor. BRAH Electric lists more than 880 replacement coils for Telemecanique, Siemens and ABB contactors and for BRAH Elite Series contactors, cross-referenced to more than 950 OEM part numbers. Listings show the coil voltage, the frequency, the amperage of the contactors the coil fits, and the family.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

1114 Results(Showing 661 - 680)
BRAH BLX1D2U6 Magnetic Coil – replaces Telemecanique LX1D2U6
BLX1D2U6
Substitute for Telemecanique LX1D2U6
View Product
Coil Voltage240VAC
Frequency60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
Telemecanique LX1D2U6 replacement Magnetic Coil – BRAH BLX1D2U6
LX1D2U6
BRAH BLX1D2U6 is the direct substitute for Telemecanique LX1D2U6
View Product
Coil Voltage240VAC
Frequency60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
BRAH BLX1D2U7 Magnetic Coil – replaces Telemecanique LX1D2U7
BLX1D2U7
Substitute for Telemecanique LX1D2U7
View Product
Coil Voltage240VAC
Frequency50/60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
Telemecanique LX1D2U7 replacement Magnetic Coil – BRAH BLX1D2U7
LX1D2U7
BRAH BLX1D2U7 is the direct substitute for Telemecanique LX1D2U7
View Product
Coil Voltage240VAC
Frequency50/60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BLX1D2W7 Magnetic Coil – replaces Telemecanique LX1D2W7
BLX1D2W7
Substitute for Telemecanique LX1D2W7
View Product
Coil Voltage277VAC
Frequency50/60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
Telemecanique LX1D2W7 replacement Magnetic Coil – BRAH BLX1D2W7
LX1D2W7
BRAH BLX1D2W7 is the direct substitute for Telemecanique LX1D2W7
View Product
Coil Voltage277VAC
Frequency50/60Hz
Amperage Contactor25A - 32A
FamilyTeSys D
BRAH BLX1D4B6 Magnetic Coil – replaces Telemecanique LX1D4B6
BLX1D4B6
Substitute for Telemecanique LX1D4B6
View Product
Coil Voltage24VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4B6 replacement Magnetic Coil – BRAH BLX1D4B6
LX1D4B6
BRAH BLX1D4B6 is the direct substitute for Telemecanique LX1D4B6
View Product
Coil Voltage24VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH BLX1D4B7 Magnetic Coil – replaces Telemecanique LX1D4B7
BLX1D4B7
Substitute for Telemecanique LX1D4B7
View Product
Coil Voltage24VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4B7 replacement Magnetic Coil – BRAH BLX1D4B7
LX1D4B7
BRAH BLX1D4B7 is the direct substitute for Telemecanique LX1D4B7
View Product
Coil Voltage24VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH BLX1D4E5 Magnetic Coil – replaces Telemecanique LX1D4E5
BLX1D4E5
Substitute for Telemecanique LX1D4E5
View Product
Coil Voltage48VAC
Frequency50Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4E5 replacement Magnetic Coil – BRAH BLX1D4E5
LX1D4E5
BRAH BLX1D4E5 is the direct substitute for Telemecanique LX1D4E5
View Product
Coil Voltage48VAC
Frequency50Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH BLX1D4E6 Magnetic Coil – replaces Telemecanique LX1D4E6
BLX1D4E6
Substitute for Telemecanique LX1D4E6
View Product
Coil Voltage48VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4E6 replacement Magnetic Coil – BRAH BLX1D4E6
LX1D4E6
BRAH BLX1D4E6 is the direct substitute for Telemecanique LX1D4E6
View Product
Coil Voltage48VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BLX1D4E7 Magnetic Coil – replaces Telemecanique LX1D4E7
BLX1D4E7
Substitute for Telemecanique LX1D4E7
View Product
Coil Voltage48VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4E7 replacement Magnetic Coil – BRAH BLX1D4E7
LX1D4E7
BRAH BLX1D4E7 is the direct substitute for Telemecanique LX1D4E7
View Product
Coil Voltage48VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH BLX1D4G6 Magnetic Coil – replaces Telemecanique LX1D4G6
BLX1D4G6
Substitute for Telemecanique LX1D4G6
View Product
Coil Voltage120VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4G6 replacement Magnetic Coil – BRAH BLX1D4G6
LX1D4G6
BRAH BLX1D4G6 is the direct substitute for Telemecanique LX1D4G6
View Product
Coil Voltage120VAC
Frequency60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
BRAH BLX1D4G7 Magnetic Coil – replaces Telemecanique LX1D4G7
BLX1D4G7
Substitute for Telemecanique LX1D4G7
View Product
Coil Voltage120VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D
Telemecanique LX1D4G7 replacement Magnetic Coil – BRAH BLX1D4G7
LX1D4G7
BRAH BLX1D4G7 is the direct substitute for Telemecanique LX1D4G7
View Product
Coil Voltage120VAC
Frequency50/60Hz
Amperage Contactor40A - 50A
FamilyTeSys D

Replacement coils by contactor family, voltage and size

Overview

Telemecanique is the largest group: TeSys D coils (types LX1D2, LX1D4, LX1D6, LX1D8, LXD1 and LX4D) for LC1D and LC2D contactors, TeSys F coils (types LX1F, LX4F and LX9F) for LC1F contactors, and TeSys K coils (type LX1KK). Siemens coverage is Sirius (type 3RT19, for 3RT contactors) and World Series (type 3TY7, for 3TF and 3TB contactors). ABB coverage is A-Line (type ZA) and EH Series (type KH).

Which replacement coil do I need for my contactor?

Two values decide the coil. The first is coil voltage and frequency. AC coils are listed from 21V up, including 24V, 120V, 208V, 240V, 277V and 480V, and DC coils from 12V to 440V; frequency is 50Hz, 60Hz or 50/60Hz. The second is the contactor the coil fits: each coil type fits a band of contactor sizes, shown as "amperage contactor for", so a 120V coil for an LC1D09 is a different part from a 120V coil for an LC1D80.

The OEM coil number carries both values, so searching for it, for example LX1D6G6, 3RT1935-5AK61 or ZA16-84, is the surest way to the right part. Magnetic coils carry a 2-year warranty from the date of invoice. Listings marked UL Listed or UL Recognized show it in their specifications.

Need help confirming a match? Call (855) 355-2724.