BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 381 - 400)
BRAH BE-TR8S300 Rating Plug – replaces General Electric TR8S300
BE-TR8S300
Substitute for General Electric TR8S300
View Product
FamilyPower Break I
Amperage300A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S300 replacement Rating Plug – BRAH BE-TR8S300
TR8S300
BRAH BE-TR8S300 is the direct substitute for General Electric TR8S300
View Product
FamilyPower Break I
Amperage300A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH BE-TR8S400 Rating Plug – replaces General Electric TR8S400
BE-TR8S400
Substitute for General Electric TR8S400
View Product
FamilyPower Break I
Amperage400A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S400 replacement Rating Plug – BRAH BE-TR8S400
TR8S400
BRAH BE-TR8S400 is the direct substitute for General Electric TR8S400
View Product
FamilyPower Break I
Amperage400A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BE-TR8S500 Rating Plug – replaces General Electric TR8S500
BE-TR8S500
Substitute for General Electric TR8S500
View Product
FamilyPower Break I
Amperage500A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S500 replacement Rating Plug – BRAH BE-TR8S500
TR8S500
BRAH BE-TR8S500 is the direct substitute for General Electric TR8S500
View Product
FamilyPower Break I
Amperage500A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH BE-TR8S600 Rating Plug – replaces General Electric TR8S600
BE-TR8S600
Substitute for General Electric TR8S600
View Product
FamilyPower Break I
Amperage600A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S600 replacement Rating Plug – BRAH BE-TR8S600
TR8S600
BRAH BE-TR8S600 is the direct substitute for General Electric TR8S600
View Product
FamilyPower Break I
Amperage600A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH BE-TR8S700 Rating Plug – replaces General Electric TR8S700
BE-TR8S700
Substitute for General Electric TR8S700
View Product
FamilyPower Break I
Amperage700A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S700 replacement Rating Plug – BRAH BE-TR8S700
TR8S700
BRAH BE-TR8S700 is the direct substitute for General Electric TR8S700
View Product
FamilyPower Break I
Amperage700A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH BE-TR8S800 Rating Plug – replaces General Electric TR8S800
BE-TR8S800
Substitute for General Electric TR8S800
View Product
FamilyPower Break I
Amperage800A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
General Electric TR8S800 replacement Rating Plug – BRAH BE-TR8S800
TR8S800
BRAH BE-TR8S800 is the direct substitute for General Electric TR8S800
View Product
FamilyPower Break I
Amperage800A
Frame Type SuitableTP, TC, THP, THC, AKR30H, AKR30S, AKR50, AKR50H
Max Frame Amp800A
BRAH BE-TSST10L Shunt Trip – replaces General Electric TSST10L
BE-TSST10L
Substitute for General Electric TSST10L
View Product
FamilyPower Break I
TypeTSST
Voltage125VDC
Frame Size Suitable2500A - 4000A
General Electric TSST10L replacement Shunt Trip – BRAH BE-TSST10L
TSST10L
BRAH BE-TSST10L is the direct substitute for General Electric TSST10L
View Product
FamilyPower Break I
TypeTSST
Voltage125VDC
Frame Size Suitable2500A - 4000A
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BE-TSST10R Shunt Trip – replaces General Electric TSST10R
BE-TSST10R
Substitute for General Electric TSST10R
View Product
FamilyPower Break I
TypeTSST
Voltage125VDC
Frame Size Suitable2500A - 4000A
General Electric TSST10R replacement Shunt Trip – BRAH BE-TSST10R
TSST10R
BRAH BE-TSST10R is the direct substitute for General Electric TSST10R
View Product
FamilyPower Break I
TypeTSST
Voltage125VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST11L Shunt Trip – replaces General Electric TSST11L
BE-TSST11L
Substitute for General Electric TSST11L
View Product
FamilyPower Break I
TypeTSST
Voltage250VDC
Frame Size Suitable2500A - 4000A
General Electric TSST11L replacement Shunt Trip – BRAH BE-TSST11L
TSST11L
BRAH BE-TSST11L is the direct substitute for General Electric TSST11L
View Product
FamilyPower Break I
TypeTSST
Voltage250VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST11R Shunt Trip – replaces General Electric TSST11R
BE-TSST11R
Substitute for General Electric TSST11R
View Product
FamilyPower Break I
TypeTSST
Voltage250VDC
Frame Size Suitable2500A - 4000A
General Electric TSST11R replacement Shunt Trip – BRAH BE-TSST11R
TSST11R
BRAH BE-TSST11R is the direct substitute for General Electric TSST11R
View Product
FamilyPower Break I
TypeTSST
Voltage250VDC
Frame Size Suitable2500A - 4000A

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.