Circuit Breaker Replacement Parts

BRAH Electric supplies aftermarket circuit breaker replacement parts: rating plugs, shunt trips, undervoltage releases and closing coils, along with face plates, lug terminal kits, mounting brackets, operating handles and other repair parts. They are made as direct replacements for parts on General Electric, Siemens, Square D, Merlin Gerin and Cutler-Hammer breakers. Each listing shows the OEM part number it replaces and the breaker family and frame it suits. Parts are factory new and carry a 2-year warranty, and same day shipping is available on most orders.

A part that replaces an OEM part number is listed under that number as well as under its BRAH part number, so the results count below can be higher than the number of parts.

492 Results(Showing 401 - 420)
BRAH BE-TSST12L Shunt Trip – replaces General Electric TSST12L
BE-TSST12L
Substitute for General Electric TSST12L
View Product
FamilyPower Break I
TypeTSST
Voltage120/240VAC
Frame Size Suitable2500A - 4000A
General Electric TSST12L replacement Shunt Trip – BRAH BE-TSST12L
TSST12L
BRAH BE-TSST12L is the direct substitute for General Electric TSST12L
View Product
FamilyPower Break I
TypeTSST
Voltage120/240VAC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST12R Shunt Trip – replaces General Electric TSST12R
BE-TSST12R
Substitute for General Electric TSST12R
View Product
FamilyPower Break I
TypeTSST
Voltage120/240VAC
Frame Size Suitable2500A - 4000A
General Electric TSST12R replacement Shunt Trip – BRAH BE-TSST12R
TSST12R
BRAH BE-TSST12R is the direct substitute for General Electric TSST12R
View Product
FamilyPower Break I
TypeTSST
Voltage120/240VAC
Frame Size Suitable2500A - 4000A
BRAH Electric factory products

Why BRAH Electric?

We're the industry leader in direct replacement.

Factory New
Drop-in fit
Matches OEM Specs
Ships Worldwide
2-Year Warranty included
BRAH BE-TSST13L Shunt Trip – replaces General Electric TSST13L
BE-TSST13L
Substitute for General Electric TSST13L
View Product
FamilyPower Break I
TypeTSST
Voltage480/600VAC
Frame Size Suitable2500A - 4000A
General Electric TSST13L replacement Shunt Trip – BRAH BE-TSST13L
TSST13L
BRAH BE-TSST13L is the direct substitute for General Electric TSST13L
View Product
FamilyPower Break I
TypeTSST
Voltage480/600VAC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST13R Shunt Trip – replaces General Electric TSST13R
BE-TSST13R
Substitute for General Electric TSST13R
View Product
FamilyPower Break I
TypeTSST
Voltage480/600VAC
Frame Size Suitable2500A - 4000A
General Electric TSST13R replacement Shunt Trip – BRAH BE-TSST13R
TSST13R
BRAH BE-TSST13R is the direct substitute for General Electric TSST13R
View Product
FamilyPower Break I
TypeTSST
Voltage480/600VAC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST7L Shunt Trip – replaces General Electric TSST7L
BE-TSST7L
Substitute for General Electric TSST7L
View Product
FamilyPower Break I
TypeTSST
Voltage12VDC
Frame Size Suitable2500A - 4000A
General Electric TSST7L replacement Shunt Trip – BRAH BE-TSST7L
TSST7L
BRAH BE-TSST7L is the direct substitute for General Electric TSST7L
View Product
FamilyPower Break I
TypeTSST
Voltage12VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST7R Shunt Trip – replaces General Electric TSST7R
BE-TSST7R
Substitute for General Electric TSST7R
View Product
FamilyPower Break I
TypeTSST
Voltage12VDC
Frame Size Suitable2500A - 4000A
General Electric TSST7R replacement Shunt Trip – BRAH BE-TSST7R
TSST7R
BRAH BE-TSST7R is the direct substitute for General Electric TSST7R
View Product
FamilyPower Break I
TypeTSST
Voltage12VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST8L Shunt Trip – replaces General Electric TSST8L
BE-TSST8L
Substitute for General Electric TSST8L
View Product
FamilyPower Break I
TypeTSST
Voltage24VDC
Frame Size Suitable2500A - 4000A
General Electric TSST8L replacement Shunt Trip – BRAH BE-TSST8L
TSST8L
BRAH BE-TSST8L is the direct substitute for General Electric TSST8L
View Product
FamilyPower Break I
TypeTSST
Voltage24VDC
Frame Size Suitable2500A - 4000A
BRAH Electric support team

Need Assistance?

Our support team is here to assist you with any inquiries or issues. Get in touch for personalized support.

Contact us

BRAH Electric products

30-day returns

Returns accepted within 30 days of shipment with an RMA; a 25–50% restocking charge applies.

Read the return policy
BRAH BE-TSST8R Shunt Trip – replaces General Electric TSST8R
BE-TSST8R
Substitute for General Electric TSST8R
View Product
FamilyPower Break I
TypeTSST
Voltage24VDC
Frame Size Suitable2500A - 4000A
General Electric TSST8R replacement Shunt Trip – BRAH BE-TSST8R
TSST8R
BRAH BE-TSST8R is the direct substitute for General Electric TSST8R
View Product
FamilyPower Break I
TypeTSST
Voltage24VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST9L Shunt Trip – replaces General Electric TSST9L
BE-TSST9L
Substitute for General Electric TSST9L
View Product
FamilyPower Break I
TypeTSST
Voltage48VDC
Frame Size Suitable2500A - 4000A
General Electric TSST9L replacement Shunt Trip – BRAH BE-TSST9L
TSST9L
BRAH BE-TSST9L is the direct substitute for General Electric TSST9L
View Product
FamilyPower Break I
TypeTSST
Voltage48VDC
Frame Size Suitable2500A - 4000A
BRAH BE-TSST9R Shunt Trip – replaces General Electric TSST9R
BE-TSST9R
Substitute for General Electric TSST9R
View Product
FamilyPower Break I
TypeTSST
Voltage48VDC
Frame Size Suitable2500A - 4000A
General Electric TSST9R replacement Shunt Trip – BRAH BE-TSST9R
TSST9R
BRAH BE-TSST9R is the direct substitute for General Electric TSST9R
View Product
FamilyPower Break I
TypeTSST
Voltage48VDC
Frame Size Suitable2500A - 4000A

Circuit breaker replacement parts by breaker family

Overview

Rating plugs make up most of this category, with replacements for GE Spectra, Power Break and MicroVersaTrip, Square D Micrologic, and Siemens breakers. Each rating plug listing shows its amperage, the frame type it suits and the maximum frame amperage.

Shunt trips, undervoltage releases and closing coils are listed by voltage and by the breaker family and frame they fit, including GE Power Break and Merlin Gerin Compact.

What each part does: a rating plug sets the ampere rating of a breaker that has an electronic trip unit. A shunt trip opens the breaker when its coil is energized, an undervoltage release opens it when control voltage is lost, and a closing coil closes it electrically. Face plates are the front nameplates of General Electric Power Break I breakers and HPC II switches. Lug terminal kits connect the cables, and operating handles, mounting brackets and repair parts such as lug caps and bumper kits cover the mechanical side of the breaker.

How do I choose a replacement circuit breaker part?

Start from the breaker nameplate, which gives the manufacturer, the family, the frame type and the frame ampere rating. For a rating plug you also need the sensor (CT) rating and the trip unit, because a plug is made for one sensor rating and one trip unit family: Spectra RMS, MicroVersaTrip RMS-9, MicroVersaTrip Plus, Siemens SB-EC or TL, or Square D MicroLogic. For shunt trips, undervoltage releases and closing coils the control voltage, AC or DC, is the second value to match. Many BRAH parts keep the OEM number with a BE- prefix, so BE-TPUV8 replaces General Electric TPUV8. If the old part is missing or its number cannot be read, the frame type and frame rating are enough to narrow the listings by family.

To find a part, filter by amperage, voltage or family, or search for the OEM part number on the part you are replacing. All BRAH circuit breaker parts carry a 2-year warranty from the date of invoice.

Need help confirming a match? Call (855) 355-2724.